Lansmont SAVER 3M30 Transport Environment Data Recorder
- Acceleration range
- 100 g
- Dimensions
- 79 × 74 × 33 mm
MEMS triaxial sensing with true DC response, recording low-frequency shock and vibration for up to 15 days
Manufacturer pageThe SAVER 3D15 is the low-frequency, DC-capable member of Lansmont's SAVER field-recorder family. It is intended for measurement applications that require DC response, meaning it can faithfully capture long-duration, constant-acceleration time histories rather than losing low-frequency content. To achieve this it uses MEMS triaxial accelerometers with DC response measurement capability, available in 5, 10, 20 and 50 g full-scale ranges, with a 3 dB frequency response that extends from DC up to the filter setting.
Amusement-park rides, aerospace flight applications, rail-car coupling impacts and vehicle crash testing all contain low-frequency responses with long-duration, constant-acceleration profiles, which is exactly where the 3D15 is used. The instrument is a self-powered, integrated unit that records full waveforms at 16-bit resolution and 50–5000 samples per second, with a 4-pole low-pass Butterworth anti-alias filter (10–500 Hz cut-off) plus built-in temperature and humidity sensors.
Power comes from user-replaceable 9V lithium or alkaline batteries, giving up to 15 days of continuous field operation. The recorder samples continuously and writes to flash memory only when a user-defined trigger threshold is exceeded, with user-defined pre-trigger recording and time-triggered recording at selectable wake-up intervals. Every acceleration time history and temperature/humidity reading is timestamped.
Collected data can be imported into SaverXware to derive drop height, impacts, vehicle motion, vibration and temperature/humidity cycles. For tasks that need both true DC low-frequency response and long unattended deployment, the 3D15 complements the higher-sampling-rate models in the same family.
| Dimensions | 95 × 74 × 43 mm (3.7 × 2.9 × 1.7 in) |
|---|---|
| Weight | 473 g (16.7 oz) |
Full datasheet on request.
| Model | Sample rate | Acceleration range | Recording duration | Temperature range |
|---|---|---|---|---|
| SAVER 3D15Current | — | — | — | — |
| SAVER 3M30 | — | 100 g | — | — |
| SAVER 3X90 | — | — | — | — |
Scroll sideways for all columns
Change the sampling rate and see how sample points describe a sine wave.
Mathematical illustration: a 5 Hz sine input. Not measured equipment data or a product performance claim. Actual selection also depends on bandwidth and anti-alias filtering.
Explore signal analyzers40 Hz sampling: approximately 8 samples per cycle.
Tell us the test object and the standard you must meet. An engineer replies within one business day.
Up to 2.5 MHz per-channel sampling with 24-bit sigma-delta ADCs, 40 analog or 2…